Sunmax Manufactureres a wide range of Domestic model Heat Pump . An innovative and environmental friendly alternative to traditional water heating systems . This KInd of Domestic heat pump is suitable for bungalow, Individual Villa ,Apartmets Etc
COMPARISON CHART FOR GEYSER AND HEAT PUMP SYSTEM
PRESSURIZED MODEL
- Your home is having 5 Bathrooms.
- Delivery of water from the rain shower size (9” X 9”) 230mm/230mm at 3 bar pressure is 25 to 30 Ltrs per minutes.
- Bathing time per person is minimum 10 minutes.
- We are assuming 5 person in your home. So, hot water requirement is 5 person X 30 ltrs X 10 minutess = 1500 lts.
- Maximum body skin temperature is 40 to 45°C.
- Total electrical unit required to heat 1500 ltrs capacity from 30 to 60°C =1500 X 1.01 X 30 /860 = 52.8 units
- Electrical heating cost is 52 uts X Rs. 8 per unit = Rs. 416/-
- Maximum capacity of Geyser available in the market is 50 ltrs with 3 kw or 6 kw filament.
- Total Electricity required is 18 kw power ( 5 bathrooms X 3kw geyser). Installing 3 kw geyser in each bathroom is 15kw power to fulfill your hot water requirement.
- Total time required to heat 50 ltrs X 1.01 X ( 65-20)=
50 X 1.01 x 45 / 860 = 2.64 kw
2.64/3 kw = 0.88
0.88 X 60 minutes = 53 minutes. Geyser connected load is 3kw. So, time required to heat 50 ltrs water is 53 minutes.
DISADVANTAGES OF GEYSER
- Its required more Electrical power.
- Its required more Time.
- Hot water storage capacity is very less.
- Its possible to get electric shock.
- Its occupying more space.
- Its require more maintenance.
- Always power supply is required to take bath.
HEAT PUMP
Total electrical unit required to heat 1500 ltrs capacity from 30 to 60°C is
- 2T Heat pump Input power = 2 kw
- 2 T Heat Pump Heating Output in kw = COP (Co –efficient of performance of Heat Pump is 4 X Input Power of the heat pump ) = 4 X 2 = 8KW So, 52 / 8KW = 6.5 hrs.
- Electricity required per 1500 ltrs for heat pump = 6.5 X 2 kw= 13 units.
- Cost of Electricity = 13 units X 8 = Rs. 104 / Day
ADVANTAGES OF HEAT PUMP
- We can save 85% of cost and Energy when compare with conventional heating system.
- 1 KW input generate 4 KW Output.
- Eco friendly and green energy product.
- 24/7 hot water supply throughout the year.
- It works in any conditional climate.
- Less area required for installation.
- Zero Maintenance when compare with solar and other heating conventional heating system
- Totally safe and reliable.
- Fashionable appearance.
- Fully Automatic Micro Controller.
- Quick Heat Generation.
- Ideal for Hospitals, Hotels, Dairies, Canteens, Industries, Govt Houses, Individual villas, Apartments etc.
- By product is cold air which can ducted and bring down the air conditioning bill.
- No waiting time for hot water as it present depend on sunshine.
COMPARISON BETWEEN SUNMAX HEAT PUMP AND OTHER BRAND HEAT PUMP
SUNMAX | OTHER BRAND |
---|---|
Sunmax Heat Pumps Manufactured in India considering Indian Standard | 100% Imported Heat Pumps |
Water Cooled Shell and tube with Nippon Grooved Copper pipe Heat Exchanger with four Pass water flow system. | Most of the Heat pump are using plate type heat exchanger. |
Our Dixell controller are designed in such a way that, they can be sustain voltage fluctuation and gives a long life span | Only used Micro Controller failure due to voltage fluctuation. |
Emersion Copeland Compressor Model Scroll Hermatically sealed with automatic overload protection | They are using Sanyo/Hitachi/Panasonic Etc., |
Lied Air make grade 3215 Micron fiber media designed 10 Micron washable filter | No filter provision. It can affect performance of heat pump |
Heat pump can run for more than 10 Hour per day | You cannot run these system for long hours very low configuration. |
Cost effective with high productivity for long life span | Systems fail and trouble frequently need to be serviced regularly. |
Heat pump spares parts we can get anywhere in India. | You have to depend only the supplier of Heat Pump |
Anyone can attend the problems of the Heat Pump | You have to depend only the supplier of Heat Pump |
No need to chemical cleaning oftenly | Should be cleaned regularly |
We take Co-efficient of performance ΔT = 30ºC | Other heat pump can take only Co-efficient of performance ΔT = 15ºC |
SPLIT AIR TO WATER HEAT PUMP
Hot water tank capacity (Ltrs) | 200 Ltrs | 300 Ltrs | 500 Ltrs |
---|---|---|---|
Rated heating Input power | 1 Kw | 1.5 Kw | 1.5Kw/ 2Kw single phase |
Rated heating output power | 4 Kw | 6 Kw | 8 Kw |
Rated Output Water Quality | 100 L/hr | 150 L/hr | 250 L/hr |
Volatage | 220V~50HZ | ||
Rated Output Water Temperature | 55 C | 55 | 55 |
Max Output Water Temperature | 60 C | ||
Compressor type | Reciprocating/Scroll | ||
No. of compressor and brand name | 1. EMERSION COPELAND | ||
Hem Exchanger pipe diameter | DN 25 | ||
Heat Exchanger Type | Shell and tube heat exchanger | ||
Draught Type | External Rotor Motor, Steel leaves | ||
Weight | 60 KG | 75 KG | 100 KG |
Control Mode | Dixell Digital Controller | ||
Protection Function | High Pressure, Low Pressure Protection, Overload Water Switch, Freeze Protection | High Pressure, Low Pressure Protec | High Pressure, Low Pressure Protec |
Dimensions L X B X H (mm) | 820 x 560 x 715 mm | 820 x 560 x 715 mm | 820 x 560 x 715 mm |